Home   

  • 830 - 856 Hinman Avenue Evanston IL 60602
    42.03341, -87.678068
    PIN: 11-19-401-025-0000
  • Local

    Within Local District?: No

    Local Dist Contrib/Non-Contrib?:

    Local Landmark?: Yes

    Year: 1986

    Local Landmark Eligible?:

    Criteria: A5: Exemplify the work of a nationally or internationally known architect, or major local architect or master builder.

  • National Register

    NR District Contrib/Non-Contrib:

    Within District?: No

    NR Landmark?: Yes

    Year: 1984

    NR Eligible?:

    Criteria:

    Alternate Address?:

  • General Information

    Category: Multi Family Residential

    Condition: Excellent

    Integrity: Excellent

    Current Use: Multi Family Residential

    Historic Use: Multi Family Residential

    Secondary Structure:

    NR Second:

  • Architectural Description

    Architectural Classification: Jacobean Revival

    Details: Copper rainwater leaders, gutters, soffits and brackets, a stone entrance with stone mullions, stone medallions and lintels, stone steps to courtyard fountain, stone fanlight, stone quoins, stone frieze, shields with garlands, and articulated parapet with stone coping and urns.

    Construction Year: 1922

    Other Year:

    Date source: Landmark Nomination

    Wall Material (Current): Brick

    Wall Material 2 (Current): Stone

    Plan: U Shape

    No of Stories: 4+

    Roof Type: Mansard

    Roof Material: Clay Tile

    Foundation: Stone

    Porch:

    Window Material: Wood

    Window Material 2: Storm Windows

    Window Type: Single Hung

    Window Configuration: 4-Apr

    Significance:

    Historic Features: Terra cotta fountain, stone stair entries, bay windows with curved top parapets, bow windows, original doors, stone water table at grade and first floor, stone entryways, mansard roof interrupted by entry columns.

    Alterations:

  • Historic Information

    Old Address (city dir.year):

    Building Moved?:

    Moved From:

    Original Owner: John A. Nyden

    Original Architect: John A. Nyden

    Architect Source: Landmark Nomination

    Builder:

    Surveyor: Susan Turner, AIS

    Surveyor Organization: The Lakota Group

    Survey Date: 15-Jun-15

    Survey Area:

  • Permit/Historic Information

    Current Address: 830 - 856 Hinman Avenue

    Old Address:

    Date of Construction: 1922

  • Permit Moving Information

    Moving Permit #:

    Date Moved:

  • Original Permit Information

    Building Permit #:

    Date:

    Building Permit Description:

    Cost:

    Original Owner Occupied?:

    Exterior Alteration Permits: 12WNDR-0174: Installation of 3 windows -- no change in size or placement; 10WNDR-0060: Replace 3 winds; 10ROOF-0385: Remove 2 layers of asph/install 30 yr asph shingles; 10MRPR-0008: Replace one window; 09ROOF-0129: Tear off roof and install tapered ISO insulation, modified bitumen top sheet; 08MSWK-0093: Tuckpoint; 08MSWK-0023: 2,500 s.f. tuckpointing, 350 s.f. brick replacement, recaulk winds, drs, seal brick, limestone repairs 830-856 Hinman;08WDW0000000007: Replace 2 windows in kind; 05DKP0000000102: 3-sty por replacement; 05RFS0000000067: Tuckpoint; 04RFS0000000205: Re-roof built-up.

    Other Permit Information: BP#92-25409, 1991.12.06, Enclose porch.

    COA Info: 12PRES-0292: Replace 3 double hung winds; 10PRES-0162: Remove asph roll roofing from the rear section of pitch rf and install asph shingles on same location (in the middle of flat roof on rear), existing roofing clay tiles to remain and not altered; 10PRES-0155: Replacing 3 double hung wood windows (single pane, with 6 over 1 divided lights) on the 3rd floor S elevation of unit #3 south, new windows are all wood double hung with 6 over 1 simulated divided lights to match the existing; 10PRES-0054: replace deteriorated double-hung wd window on the 3rd floor W elevation with new double-hung wd window (SDL) to match existing window and dimensions of glass area; 08HIS0000000057: Replace two double hung wd winds on the SE corner of the blding (APT. 3S) with two new double hung wd winds to match the existing; 08HIS0000000051: 2,500 S.F. of spot tuckpointing, 350 sf of various brick replacement, recaulk all perimeter doors, winds and penetrations, power wash and seal all brick and mortar joints, limestone repairs and pin loose coping stones; 06HIS0000000010: Replace three 3-sty pors at W elevation on alley side [Alteration], approved 2006.07.02.

    Historic Info:

    Other Sources:

    Historic Info Compiler:

    Volunteer: Tyner

Print-Friendly PDF
© 2023 PlaceVision Inc | Help | Privacy